Gas panel - Blood   24338-6

LOINC Code


LOINC code24338-6
nameGas panel - Blood
descriptionKnowing the concentration of inspired O2 is important to the interpretation of PO2 results. Inspired O2 can be recorded in two ways- as percent- of O2 delivered to the patient (Venturi mask, re-breather mask, or ventilator) or as liters of oxygen per minute (nasal canula). This panel includes terms for recording the inspired O2 in either fashion. But because only one will apply and labs do not always receive this information they are designated as optional. The term "oxygen saturation" is often used to refer to two distinctly different quantities, hemoglobin oxygen saturation (recommended symbol = sO2) and fractional oxyhemoglobin (recommended symbol = FO2Hb). The former is sometimes called functional oxygen saturation and the later, fractional oxygen saturation Hemoglobin oxygen saturation = is the amount of oxyhemoglobin expressed as the percent of the hemoglobin able to bind oxygen, i.e. oxyhemoglobin (O2Hb) + deoxyhemoglobin (HHb). sO2 = 100 x O2Hb/ (O2Hb + HHb) Fractional oxyhemoglobin = the amount of oxyhemoglobin expressed as a percent of the total hemoglobin, where tHb = O2Hb + HHb + [COHb + MetHb + SulfHb]. Note that COHb, MetHb, and SulfHb, cannot carry oxygen and are thus called dyshemoglobins. FO2Hb = O2Hb/tHb Gas machines that can measure carbon monoxide, could, in principle, also report FO2Hb, and we had assumed that they would. However, at least some machines that do measure COHb and MetHb provide no option for reporting FO2Hb, and report only sO2. When mapping blood gas panels that report COHb% and also report FO2Hb, map that term to the LOINC term with the component of "Oxyhemoglobin /Total hemoglobin". If such an instrument reports only "oxygen saturation, verify with the lab that they are really reporting a functional O2 sat and not the Fractional Oxyhemoglobin, because the two are not always correctly labeled. If it is sO2 then map it to the LOINC term with a component of "Oxygen saturation". When you are mapping data from a simpler Blood gas instrument (one that can read fewer than 4 wave lengths), then the O2 saturation will likely be a sO2. So map also moat that variable to the LOINC with a component of "Oxygen Saturation". (Source: McD derived from Gill and McD- 2009 09)
statusACTIVE

Fully-Specified Name

componentGas panel
property-
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBld  =  Whole blood
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
method

Additional Names

short nameGas Pnl Bld

Basic Attributes

classPANEL.CHEM
type1  Laboratory
order vs. observationOrder

Panel Components

11558-4pH of Blood
33254-4pH of Arterial blood adjusted to patient's actual temperature
11557-6Carbon dioxide [Partial pressure] in Blood
34705-4Carbon dioxide [Partial pressure] adjusted to patient's actual temperature in Blood
11556-8Oxygen [Partial pressure] in Blood
19254-2Oxygen [Partial pressure] adjusted to patient's actual temperature in Blood
57800-5Oxygen content in Blood by calculation
1959-6Bicarbonate [Moles/volume] in Blood
20565-8Carbon dioxide, total [Moles/volume] in Blood
11555-0Base excess in Blood by calculation
30318-0Base deficit in Blood
20564-1Oxygen saturation in Blood
2713-6Oxygen saturation Calculated from oxygen partial pressure in Blood
718-7Hemoglobin [Mass/volume] in Blood
3150-0Inhaled oxygen concentration
3151-8Inhaled oxygen flow rate
8310-5Body temperature

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

test rank1444 of 2000 most commonly performed tests by labs in USA
order rank257 of 2000 most commonly ordered tests by labs in USA
first released
last updated2.73
last change typeMIN  - change to field other than name

Related Names

BGas
Blood
Blood gas
Blood gases
Chemistry
Gas Pnl
Gases
Pan
PANEL.CHEMISTRY
Panl
Pnl
Point in time
QNT
Quan
Quant
Quantitative
Random
WB
Whole blood

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.