Chest tube output 24 hour Pleural space - right 32387-3
LOINC Code
LOINC code | 32387-3 | ||
---|---|---|---|
name | Chest tube output 24 hour Pleural space - right | ||
status | ACTIVE | ||
Fully-Specified Name | |||
component | Chest tube output.total | ||
property | VRat = Volume Rate | ||
time | 24H = 24 hours | ||
system | Pleural space.right | ||
scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | ||
method | |||
Additional Names | |||
short name | Chest tube output 24h Pl space-R | ||
Basic Attributes | |||
class | IO_OUT.TIMED.MOLE | ||
type | 2 Clinical | ||
example UCUM units | mL/(24.h) The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | ||
example unit | mL/24 H | ||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
History/Usage | |||
first released | |||
last updated | 2.48 | ||
last change type | MIN - change to field other than name | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.
Thank you for choosing Find-A-Code, please Sign In to remove ads.