Clotting time.extrinsic coagulation system activated.fibrinolysis suppressed of Blood by Rotational TEG   52774-7

LOINC Code


LOINC code52774-7
nameClotting time.extrinsic coagulation system activated.fibrinolysis suppressed of Blood by Rotational TEG
statusACTIVE

Fully-Specified Name

componentClotting time.extrinsic coagulation system activated.fibrinolysis suppressed
propertyTime  =  Time Duration
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBld  =  Whole blood
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodThromboelastography.rotational

Additional Names

short nameCT.fibinolysis supp Bld ROTEM

Basic Attributes

classCOAG
type1  Laboratory
order vs. observationObservation
example UCUM unitss
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example units

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Panels

52764-8Extrinsic coagulation system with fibrinolysis inhibition thromboelastography panel - Blood

History/Usage

test rank1990 of 2000 most commonly performed tests by labs in USA
first released
last updated2.73
last change typeMIN  - change to field other than name
change reasonUpdated Method from Thromboelastography to clarify that the Method used for this assay is rotational TEG ("ROTEM") and to distinguish from the original thromboelastography and new resonance thromboelastography Methods.

Related Names

Activ
Blood
Clot
Clottable
Coag
Coagulation time
CT.extrinsic
CT.fibinolysis supp
Hematology
Heme
Point in time
QNT
Quan
Quant
Quantitative
Random
Rate
ROTEM
R-time
TEG
TEM
Thrombelastography
Thrombelastometry
Thromboelastometry
WB
Whole blood

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.