Maximum clot firmness.extrinsic coagulation system activated.fibrinolysis suppressed [Length] in Blood by Rotational TEG   52779-6

LOINC Code


LOINC code52779-6
nameMaximum clot firmness.extrinsic coagulation system activated.fibrinolysis suppressed [Length] in Blood by Rotational TEG
statusACTIVE

Fully-Specified Name

componentMaximum clot firmness.extrinsic coagulation system activated.fibrinolysis suppressed
propertyLen  =  Length
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBld  =  Whole blood
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodThromboelastography.rotational

Additional Names

short nameMCF.fibrinolysis supp Bld ROTEM

Basic Attributes

classCOAG
type1  Laboratory
order vs. observationObservation
example UCUM unitsmm
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitmm

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Panels

52764-8Extrinsic coagulation system with fibrinolysis inhibition thromboelastography panel - Blood

History/Usage

first released
last updated2.70
last change typeMIN  - change to field other than name
change reasonUpdated Method from Thromboelastography to clarify that the Method used for this assay is rotational TEG ("ROTEM") and to distinguish from the original thromboelastography and new resonance thromboelastography Methods.

Related Names

Activ
Blood
CF
Coag
Hematology
Heme
Length
MA
Maximum amplitude
MCF
MCF.extrinsic
MCF.fibrinolysis supp
Point in time
QNT
Quan
Quant
Quantitative
Random
ROTEM
TEG
TEM
Thrombelastography
Thrombelastometry
Thromboelastometry
WB
Whole blood

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.