HIV 1+2 IgG Ab [Presence] in Serum or Plasma by Rapid immunoassay   73905-2

LOINC Code


LOINC code73905-2
nameHIV 1+2 IgG Ab [Presence] in Serum or Plasma by Rapid immunoassay
descriptionHIV-1 and/or HIV-2 IgG antibodies can be detected in serum or plasma specimens by rapid immunoassays. Results are used for HIV screening in community, public health, and clinical settings. This code is based on, but not limited in use to, Alere's Clearview COMPLETE HIV 1/2 immunochromatographic assay, which detects but does not differentiate between HIV 1 & 2 IgG antibodies. It takes approximately 15-20 minutes to complete.
statusACTIVE

Fully-Specified Name

componentHIV 1+2 Ab.IgG
propertyPrThr  =  Present or threshold:  The Property PrThr stands for “Presence or Threshold”, meaning either a) the actual presence or absence of an analyte, or b) that the amount of analyte detected is over some predetermined threshold.
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemSer/Plas
    Ser  =  Serum
    Plas  =  Plasma
scaleOrd  =  Ordinal:  Ordered categorical responses, e.g., 1+, 2+, 3+; positive, negative; reactive, indeterminate, nonreactive.
methodIA.rapid

Additional Names

short nameHIV1+2 IgG SerPl Ql IA.rapid

Basic Attributes

classMICRO
type1  Laboratory
order vs. observationBoth

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Panels

75622-1HIV 1 and 2 tests - Meaningful Use set

History/Usage

test rank17659 of 2000 most commonly performed tests by labs in USA
first released
last updated2.73
last change typeMIN  - change to field other than name
change reasonThe PrThr property is used for LOINC terms whose results are reported using an ordered categorical scale, regardless of whether or not an internal threshold was used to make that determination. This change was approved by the Laboratory LOINC Committee in June 2016.; The EIA method, which was always intended to cover more than just enzyme-linked immunoassay and whose display name for the long common name has always been Immunoassay, was renamed IA in order to eliminate ambiguity about whether the method has a broader meaning than just enzyme-linked immunoassay. Likewise, EIA.rapid was renamed IA.rapid. These changes were approved by the Laboratory LOINC Committee in June 2016.

Related Names

ABS
Aby
AIDS
Antby
Anti
Antibodies
Antibody
Autoantibodies
Autoantibody
EIA
ELFA
ELISA
Enzyme immunoassay
HIV 1 & 2
HIV 1 and 2 Ab
HIV type 1
HIV type I
HIV1
HIV1+2
Human immunodeficiency virus
i
IAA
ID
II
Immune globulin G
Immunoglobulin G
Infectious Disease
InfectiousDisease
MEIA
Microbiology
Ordinal
Pl
Plasma
Plsm
Point in time
PR
QL
Qual
Qualitative
Random
Screen
SerP
SerPl
SerPlas
Serum
Serum or plasma
SR
SUDS

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.