Left atrial End-systolic volume by US.2D+Calculated by modified Simpson method 77904-1
LOINC Code
LOINC code | 77904-1 | ||
---|---|---|---|
name | Left atrial End-systolic volume by US.2D+Calculated by modified Simpson method | ||
description | The modified Simpson method is commonly used for volume measurements in 2D cardiac imaging. It uses the biplane method of disks, meaning that the total volume is calculated by adding together the two-dimensional area measurements of the series of circular or elliptical slices that, taken as a whole, represent the chamber being measured. [PMID: 16376782] | ||
status | ACTIVE | ||
Fully-Specified Name | |||
component | End-systolic volume | ||
property | Vol = Volume | ||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
system | Heart.atrium.left | ||
scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | ||
method | US.2D+Calculated by modified Simpson method | ||
Additional Names | |||
short name | LA ES vol US.2D+mod Simpson | ||
Basic Attributes | |||
class | CARD.US | ||
type | 2 Clinical | ||
order vs. observation | Observation | ||
example UCUM units | mL The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | ||
example unit | mL | ||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
History/Usage | |||
first released | |||
last updated | 2.52 | ||
last change type | MIN - change to field other than name | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.
Thank you for choosing Find-A-Code, please Sign In to remove ads.