Activity level [Acceleration]   80493-0

LOINC Code


LOINC code80493-0
nameActivity level [Acceleration]
descriptionActivity level is calculated as vector magnitude units (VMU) based on axial accelerations in all three dimensions and is reported in gravity (g) units. This term was created for, but is not limited in use to, the Zephyr BioHarness, a physiological monitoring belt device that captures and transmits multiple physiologic parameters.
statusACTIVE

Fully-Specified Name

componentActivity level
propertyAccel  =  Acceleration
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
system^Patient
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
method

Additional Names

short nameActivity level Accel

Basic Attributes

classCLIN
type2  Clinical
order vs. observationObservation
formula (readable)Activity level = Vector magnitude units (VMU) = SUM[SQR RT(x^2+y^2+z^2)] for each 1 second time epoch/number of time epochs, where x, y and z are the axial accelerations in each individual dimension.
example UCUM units[g]
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitg units

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Groups

LG41761-4Exercise/Activity

Member of these Panels

82611-5Wearable device external physiologic monitoring panel

History/Usage

test rank5420 of 2000 most commonly performed tests by labs in USA
first released
last updated2.73
last change typeMIN  - change to field other than name

Related Names

Acceleration
Accelerometer
Activ
Activity
Actvty
CLIN
Exercise
Levels
Levl
LV
LVL
Movements
Point in time
QNT
Quan
Quant
Quantitative
Random

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.