Liver ultrasound attenuation by transient elastography   81894-8

LOINC Code


LOINC code81894-8
nameLiver ultrasound attenuation by transient elastography
descriptionA measure of the attenuation of the ultrasound signal (loss of energy) as it travels through and returns from the liver at 3.5 MHz, often reported simultaneously with liver stiffness [LOINC:77615-3]. Based on the principle that ultrasound propagation is affected by tissue fat content, the ultrasound attenuation measurement, referred to as Controlled Attenuation Parameter (CAP), is a measure of liver fat content (steatosis) and expressed in dB/m. Increasing steatosis is associated with higher levels of signal attenuation. [PMID: 22404722]
statusACTIVE

Fully-Specified Name

componentUltrasound attenuation
propertyPres  =  Pressure
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemLiver
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodUS.transient elastography

Additional Names

short nameUS.TE Liver attenuation

Basic Attributes

classRAD
type2  Clinical
order vs. observationBoth
example UCUM unitsdB
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitdB/m

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.66
last change typeMIN  - change to field other than name

Related Names

CAP
Controlled Attenuation Parameter
Echography
Fibroscan
Hepar
Hepatic
Hepatology
Imaging
Liver
Point in time
Pressure
QNT
Quan
Quant
Quantitative
RADIOLOGY
Random
Sonogram
Sonograph
Sonography
Steatosis, Liver
ULS
Ultrasound
US.TE

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.