Osmolarity in Tear   85382-0

LOINC Code


LOINC code85382-0
nameOsmolarity in Tear
descriptionThe osmolarity or concentration of the ocular tear fluid will indicate if the patient is being affected by dry eye disease, which would result in a hyperosmolar tear fluid caused by either the reduction of tear fluid production by the lacrimal gland or the abnormal increase in evaporation of the tear fluid on the surface of the eye. A hyperosmolar tear film is toxic to the ocular surface resulting in cell damage, apoptosis, inflammation and an unstable tear film contributing to abnormal visual acuity. This term was created for, but is not limited in use to, the submitter's TearLab Osmolarity System.
statusACTIVE

Fully-Specified Name

componentOsmolarity
propertyOsmolarity  =  Osmolarity:  the concentration of a solution expressed as the total number of solute particles per liter
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemTear  =  Tears
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
method

Additional Names

short nameOsmolarity Tear

Basic Attributes

classCHEM
type1  Laboratory
order vs. observationObservation
example UCUM unitsmosm/L
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitmOsm/L

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.61
last change typeADD  - added

Related Names

Chemistry
Point in time
QNT
Quan
Quant
Quantitative
Random
Tears

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.