Pulmonary artery End diastolic blood pressure by Cardiac catheterization 94123-7
LOINC Code
LOINC code | 94123-7 | ||
---|---|---|---|
name | Pulmonary artery End diastolic blood pressure by Cardiac catheterization | ||
description | Diastolic pulmonary artery pressure (dPAP) is used with pulmonary artery wedge pressure (PAWP) to help distinguish post-capillary pulmonary hypertension from combined post- and pre-capillary pulmonary hypertension associated with left heart failure. The diastolic pressure gradient (DPG) is calculated as dPAP minus PAWP, and is an alternate to the transpulmonary pressure gradient (TPG), which is calculated as the mean pulmonary artery pressure (mPAP) minus PAWP. An elevated DPG or TPG indicates that the increase in pulmonary pressure is not solely due to increased PAWP (post-capillary), but rather has a pre-capillary component as well, as reflected in an dPAP/mPAP increase out of proportion to PAWP. [PMID: 27587711] | ||
status | ACTIVE | ||
Fully-Specified Name | |||
component | Intravascular end diastolic | ||
property | Pres = Pressure | ||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
system | Pulmonary artery | ||
scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | ||
method | Cardiac catheterization | ||
Additional Names | |||
short name | dPAP by Cardiac cath | ||
Basic Attributes | |||
class | BP.CENT.MOLEC | ||
type | 2 Clinical | ||
order vs. observation | Observation | ||
example UCUM units | mm[Hg] The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | ||
example unit | mm Hg | ||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
History/Usage | |||
first released | |||
last updated | 2.67 | ||
last change type | ADD - added | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.