Clot strength TXA2 receptor inhibited [Length fraction] in Blood by calculation   94578-2

LOINC Code


LOINC code94578-2
nameClot strength TXA2 receptor inhibited [Length fraction] in Blood by calculation
descriptionA calculated value representing the relative amount of clotting strength (i.e., platelet activity) that would remain in the presence of anti-platelet thromboxane A2 (TXA2)-receptor inhibiting drugs. It is the portion of clotting strength due to factors other than arachidonic acid, which activates platelets by a pathway that includes metabolism to thromboxane A2 (TXA2), which binds to the TXA2 receptor. This result is used to guide anti-platelet therapy decisions. For example, if a patient's baseline relative clotting strength due to AA activation is 25% [LOINC: 94579-0], then treating that patient with an anti-platelet TXA2 receptor inhibitor would only reduce clotting strength by 25%, leaving a predicted 75% intact.
statusACTIVE

Fully-Specified Name

componentClot strength.platelet thromboxane A2 receptor inhibited
propertyLenFr  =  Length Fraction
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBld  =  Whole blood
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodCalculated

Additional Names

short nameClot strength TXA2-R inhib LenFr Bld

Basic Attributes

classCOAG
type1  Laboratory
order vs. observationObservation
formula (readable)100 - [{(MAaa - MAactF) / (MAk - MAactF) } x 100], where MAaa, MAactF, and MAk are the maximum amplitude induced by arachidonic acid, activator F, and kaolin, respectively.
example UCUM units%
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unit%

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.68
last change typeADD  - added

Related Names

AA % inhibition
Blood
Calc
Calculation
Clot strength TXA2-R inhib
COAGULATION
Hematology
Heme
Length Fraction
Percent
Pl
Platelets
Platelt
Plt
Point in time
QNT
Quan
Quant
Quantitative
Random
Rec
Recept
Receptors
Recp
Recptr
Thrombocyte
Thrombocytes
Tx
WB
Whole blood

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.