Maximum amplitude tissue factor induced+platelet glycoprotein IIb-IIIa receptor inhibited [Length] in Blood by Resonance TEG   97014-5

LOINC Code


LOINC code97014-5
nameMaximum amplitude tissue factor induced+platelet glycoprotein IIb-IIIa receptor inhibited [Length] in Blood by Resonance TEG
descriptionResonance thrombelastography determination of fibrin clot strength, stimulated with tissue factor, and platelets inhibited by a platelet glycoprotein IIb-IIIa receptor inhibitor such as abciximab. The maximum amplitude (MA) in TEG reflects both a plasmatic and platelet component. By including abciximab to inhibit binding of fibrin and fibrinogen to GPIIb/IIIa receptors, the platelet effect on MA is removed (at least partly), allowing more specific treatment of the patient. [PMID:14717978]
statusACTIVE

Fully-Specified Name

componentMaximum clot strength amplitude.tissue factor induced+platelet glycoprotein IIb-IIIa receptor inhibited
propertyLen  =  Length
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBld  =  Whole blood
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodThromboelastography.resonance

Additional Names

short nameMA TF ind+IIb-IIIa inh Bld Res TEG

Basic Attributes

classCOAG
type1  Laboratory
order vs. observationObservation
example UCUM unitsmm
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitmm

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.70
last change typeADD  - added

Related Names

Blood
COAGULATION
Fac
Fact
gG
Glycoprot
Glycoproteins
GP
Hematology
Heme
Length
MA TF ind+IIb-IIIa inh
Pl
Plat Gp
Plat Gp IIb/IIIa
Platelets
Platelt
Plt
Point in time
QNT
Quan
Quant
Quantitative
Random
Rec
Recept
Receptors
Recp
Recptr
Res TEG
TEG
Thrombelastography
Thrombelastometry
Thrombocyte
Thrombocytes
WB
Whole blood

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.