Platelet aggregation ADP induced [Units/volume] in Platelet rich plasma 49010-2
LOINC Code
LOINC code | 49010-2 | ||
---|---|---|---|
name | Platelet aggregation ADP induced [Units/volume] in Platelet rich plasma | ||
description | Assay is used to measure platelet P2Y12 receptor blockade known to occur with some drugs including the thienopyridine class of drugs, including clopidogrel (Plavis(r)). VerifyNow P2Y12 Assay from Accumetrics uses adenosine-5-diphosphate(ADP/PGE1) to induce platelet activation. Activated platelets bind fibrinogen in proportion to the number of expressed platelet GPIIb/IIIa receptors. Light transmittance increases as activated platelets bind and aggregate the fibrinogen-coated beads. A turbidimetric based optical detection system measures change in optical signal caused by aggregation and reports results in P2Y12 Reaction Units(PRU). Information from VerifyNow P2Y12 Assay package insert from Accumetrics dated 2006 09 01 | ||
status | ACTIVE | ||
Fully-Specified Name | |||
component | Platelet aggregation.adenosine diphosphate induced | ||
property | ACnc = Arbitrary Concentration | ||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
system | PRP = Platelet rich plasma | ||
scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | ||
method | |||
Additional Names | |||
short name | PA ADP PRP-aCnc | ||
Basic Attributes | |||
class | COAG | ||
type | 1 Laboratory | ||
order vs. observation | Both | ||
example UCUM units | [arb'U] The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | ||
example unit | PRU | ||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
History/Usage | |||
test rank | 3343 of 2000 most commonly performed tests by labs in USA | ||
first released | |||
last updated | 2.73 | ||
last change type | MIN - change to field other than name | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.
Thank you for choosing Find-A-Code, please Sign In to remove ads.