PhenX - respiratory - arterial blood gas - ABG protocol 090201   62613-5

LOINC Code


LOINC code62613-5
namePhenX - respiratory - arterial blood gas - ABG protocol 090201
descriptionThis protocol describes the procedures for blood collection for arterial blood gas (ABG) analysis. It involves puncturing an artery with a thin needle and syringe and drawing a small volume of blood. The most common puncture site is the radial artery at the wrist, but sometimes the femoral artery in the groin or other sites are used.
statusTRIAL

Fully-Specified Name

componentPhenX - respiratory - arterial blood gas - ABG protocol 090201
property-
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
system^Patient
scale-
methodPhenX

Additional Names

short nameResp arterial blood gas proto

Basic Attributes

classPANEL.PHENX
type2  Clinical

Panel Components

64111-8Time at blood draw
8310-5Body temperature
8361-8Body position with respect to gravity
64022-7Patients activity level [PhenX]
9279-1Respiratory rate
20506-2Specimen drawn from
35503-2Arterial patency Wrist artery --pre arterial puncture
3150-0Inhaled oxygen concentration
19941-4Oxygen gas flow Oxygen delivery system
64023-5Mode of supported ventilation [PhenX]
2019-8Carbon dioxide [Partial pressure] in Arterial blood
2703-7Oxygen [Partial pressure] in Arterial blood
2744-1pH of Arterial blood
718-7Hemoglobin [Mass/volume] in Blood
11559-2Fractional oxyhemoglobin in Blood
20563-3Carboxyhemoglobin/Hemoglobin.total in Blood
2614-6Methemoglobin/Hemoglobin.total in Blood

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Panels

62611-9PhenX domain - Respiratory

History/Usage

first released
last updated2.66
last change typeNAM  - change to Analyte/Component
change reasonUpdated the PhenX ID from "PhenX." to "PX" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.

Related Names

Gases
Pan
Panel
PANEL.PHENX
Panl
Pnl
Point in time
Random
Resp arterial blood gas proto

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.