PhenX - respiratory - spirometry protocol 091601   62639-0

LOINC Code


LOINC code62639-0
namePhenX - respiratory - spirometry protocol 091601
descriptionA spirometric test requires that the subject take a full, deep breath and then exhale as forcefully as possible into a hand-held portable spirometer. The subject's effort is called the forced expiratory maneuver and most commonly measures the amount and speed of air that is exhaled. The total amount (volume) of air exhaled is called the forced vital capacity (FVC). The amount (volume) of air exhaled in 1 second is called the forced expiratory volume in 1 second (FEV1). While hand-held spirometers are commonly used in clinical research studies, the same results can be obtained from more sophisticated floor-mounted devices that are typically available in a respiratory function testing laboratory. Numerous instructions are embedded in the protocol and in Table 1 of the protocol.
statusTRIAL

Fully-Specified Name

componentPhenX - respiratory - spirometry protocol 091601
property-
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
system^Patient
scale-
methodPhenX

Additional Names

short nameResp spirometry proto

Basic Attributes

classPANEL.PHENX
type2  Clinical

Panel Components

64591-1Data type [PhenX]
20053-5Atmospheric pressure
60832-3Room temperature
65643-9Relative humidity
64592-9FVC quality attribute Respiratory system [PhenX]
64593-7FEV1 quality attribute Respiratory system [PhenX]
64594-5Effort attribute [PhenX]
64595-2Deleted maneuver [PhenX]
64596-0Acceptable maneuver [PhenX]
64597-8Technician quality control code [PhenX]
64598-6Computer quality code [PhenX]
64599-4Plateau achieved [PhenX]
64600-0Review status [PhenX]
65644-7BTPS factor [Ratio] [PhenX]
64601-8Date of review [PhenX]
65645-4Reviewer initials
65646-2Manufacturer name Oxygen saturation device
41927-5Oxygen saturation device Vendor model code
41928-3Oxygen saturation device Vendor serial number
41925-9Type of Oxygen saturation device
65652-0Testing facility name
65647-0City Facility
52830-7State, district or territory federal abbreviation Facility
45401-7Postal code [Location]
65649-6Country Facility
65650-4Email address Facility
65651-2Phone number Facility
64991-3Date of observation
64603-4Calibration result
64991-3Date of observation
64604-2Technician [Identifier]
64605-9Maneuver number [PhenX]
30525-0Age
3137-7Body height Measured
3141-9Body weight Measured
46098-0Sex
64606-7Race - 2 character code [PhenX]
21112-8Birth date
64607-5Reference values source [PhenX]
65817-9Reference values correction factor PhenX
64608-3Testing position [PhenX]
65653-8Test challenge type Respiratory system
65818-7Medication [Mass/volume] Dose
65866-6Methacholine [Mass] of Dose
19868-9Forced vital capacity [Volume] Respiratory system by Spirometry
65654-6Extrapolated volume Respiratory system
20150-9FEV1
65655-3FEV6
33452-4Maximum expiratory gas flow Respiratory system airway
19945-5Gas flow FEV 25%-75% airway
19866-3Vital capacity [Volume] Respiratory system by Spirometry
65819-5Forced expiratory time
65820-3Time to expiratory gas flow.max
19869-7Forced vital capacity [Volume] Respiratory system Predicted
20149-1FEV1 Predicted
65656-1FEV6 Predicted
19925-7FEV1/FVC Predicted
65658-7FEV1/FEV6 Predicted
8251-1Service comment
65660-3Original sampling interval [PhenX]
65821-1Gas flow FEV 25%
65822-9Gas flow FEV 50%
65823-7Gas flow FEV 75%
65824-5Gas flow FEV 90%
65661-1Data points [#] [PhenX]
65662-9Flow time data point [PhenX]

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Panels

62611-9PhenX domain - Respiratory

History/Usage

first released
last updated2.66
last change typeNAM  - change to Analyte/Component
change reasonUpdated the PhenX ID from "PhenX." to "PX" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.

Related Names

Pan
Panel
PANEL.PHENX
Panl
Pnl
Point in time
Random
Resp spirometry proto

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.