PhenX - intraocular pressure protocol 110701   62691-1

LOINC Code


LOINC code62691-1
namePhenX - intraocular pressure protocol 110701
descriptionIntraocular pressure (IOP) is measured using the TONO-PEN® XL instrument. The cornea is prepared by introducing one drop of anesthetic onto the surface of the eye and the TONO-PEN® is used to obtain four valid IOP measurements. The instrument calculates an average and the examiner records the average. The instrument also provides the reliability level of the measurement. Only those readings that have a 5% variability level are recorded as they are considered to be accurate. This protocol uses TONO-PEN® to measure intraocular pressure. This instrument has the advantages of portability and is relatively easy to use. Other hand-held instruments can be used to measure intraocular pressure. If other instruments are used, the reproducibility of the measurements should be comparable to those acquired with this protocol. In addition, when other instruments are used to collect these measurements, the manufacturer and model of equipment should be recorded. These other devices may require some different steps than are described in this protocol. Investigators should follow the equipment manufacturer's instructions to ensure quality control.
statusTRIAL

Fully-Specified Name

componentPhenX - intraocular pressure protocol 110701
property-
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
system^Patient
scale-
methodPhenX

Additional Names

short nameIntraocular pressure proto

Basic Attributes

classPANEL.PHENX
type2  Clinical

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Panels

62677-0PhenX domain - Ocular

History/Usage

first released
last updated2.66
last change typeNAM  - change to Analyte/Component
change reasonUpdated the PhenX ID from "PhenX." to "PX" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.

Related Names

IOP
Pan
Panel
PANEL.PHENX
Panl
Pnl
Point in time
Random

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.