PhenX - retinal digital photography protocol 111501   62709-1

LOINC Code


LOINC code62709-1
namePhenX - retinal digital photography protocol 111501
descriptionTwo 45 digital retinal images (Field 1 and 2) will be taken of each eye of the participant using the Canon Non-Mydriatic Retinal CR6-45NM camera with a digital Canon D60 camera back (6.3 megapixels per image). Field 1 is centered on the optic disc and Field 2 is centered on the macula, providing photographic documentation of the optic disc, macula, and substantial portions of the temporal arcades. These photographs may be graded for retinal microvascular characteristics, including focal arteriolar narrowing, arterio-venous nicking, retinopathy (e.g., microaneurysms, retinal hemorrhages) and other conditions. In addition, generalized arteriolar narrowing is quantified using a computer assisted measure of retinal vascular caliber. Training to take consistent gradable images is required although training is not extensive and quality of photography should be monitored throughout the entire study. Systematic grading of the images with adequate quality control procedures is imperative to minimize grader variability and to minimize misclassification leading to spurious or erroneous null findings. This protocol uses the Canon Non-Mydriatic Retinal CR6-45NM camera with a digital Canon D60 camera back (6.3 megapixels per image). Other ophthalmic imaging cameras can be used. If other instruments are used, the reproducibility of the measurements should be comparable to those acquired with this protocol. The Ocular Working Group recommends cameras that capture images that are 5 mega-pixels or larger for use in grading and vessel measurement protocols. When other instruments are used to capture digital retinal images, the manufacturer and model of equipment should be recorded. These other cameras may require some different steps than are described in this protocol. Investigators should follow the equipment manufacturer's instructions to ensure quality control. In addition, this protocol uses EyeQSL,software which is commercially available through Digital Healthcare Inc. The Ocular Working Group notes that other ophthalmic imaging packages are available through other vendors that are similar in nature. These other software packages may require some different steps than are described in this protocol. Investigators should follow the manufacture's instructions to ensure quality control. Please be sure to record the manufacturer and model and version of the software used.
statusTRIAL

Fully-Specified Name

componentPhenX - retinal digital photography protocol 111501
property-
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
system^Patient
scale-
methodPhenX

Additional Names

short nameRetinal digital photography proto

Basic Attributes

classPANEL.PHENX
type2  Clinical

Panel Components

46496-6Agency patient number during assessment period [CMS Assessment]
65884-9Photographer ID
65883-1Retinal digital photog device Vendor model number
65898-9Eye fields photographed in the retinal digital photography Right eye [Retinal digital photography]
65899-7Other eye field Right eye [Retinal digital photography]
65900-3Retinal digital photog device Flash setting in the retinal digital photography Retinal digital photography
65901-1Number Images captured in the retinal digital photography
65902-9Estimated diameter of pupil Right eye [Retinal digital photography]
65903-7Problems or unusual findings Right eye
65904-5Eye fields photographed in the retinal digital photography Left eye [Retinal digital photography]
65905-2Other eye field Left eye [Retinal digital photography]
65900-3Retinal digital photog device Flash setting in the retinal digital photography Retinal digital photography
65901-1Number Images captured in the retinal digital photography
65906-0Estimated diameter of pupil Left eye [Retinal digital photography]
65907-8Problems or unusual findings Left eye

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Panels

62677-0PhenX domain - Ocular

History/Usage

first released
last updated2.66
last change typeNAM  - change to Analyte/Component
change reasonUpdated the PhenX ID from "PhenX." to "PX" in Survey Question Source field to align with the variable identifier used in the PhenX Toolkit.; Added the PhenX protocol ID to the Component to clearly define the protocol version for which this panel is based upon.

Related Names

Pan
Panel
PANEL.PHENX
Panl
Pnl
Point in time
Random
Retinaldehyde
Retinene
Retinene 1
Vit A aldehyde
Vit A1 aldehyde
Vitamin A aldehyde
Vitamin A1 aldehyde

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.