PhenX - audiogram hearing test protocol 200101 62977-4
LOINC Code
LOINC code | 62977-4 | ||
---|---|---|---|
name | PhenX - audiogram hearing test protocol 200101 | ||
description | The National Health and Nutrition Examination Survey (NHANES) 2008-2009 audiometry protocol tests the examinee's hearing threshold (in decibels, dB) at 7 frequencies in a soundproof room. Examinees are asked a series of exclusionary questions, undergo an outer-ear examination (otoscopy), and then have the mobility of their eardrum tested (acoustic immittance). Pure tone signals are then presented to each ear through earphones and the intensity of the signals is varied until the level is identified at which the person is just able to hear the sound. An audiogram should be conducted in a soundproof room or booth to permit accurate hearing threshold measurements. Although the 2009-2010 National Health and Nutrition Examination Survey (NHANES) conducts pure tone audiometry on individuals ages 12-19 years and older than 70 years, previous versions of the National Health and Nutrition Examination Survey have performed this procedure on children as young as 4 years and adults of all ages. | ||
status | TRIAL | ||
Fully-Specified Name | |||
component | PhenX - audiogram hearing test protocol 200101 | ||
property | - | ||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
system | ^Patient | ||
scale | - | ||
method | PhenX | ||
Additional Names | |||
short name | Audiogram hearing test proto | ||
Basic Attributes | |||
class | PANEL.PHENX | ||
type | 2 Clinical | ||
Panel Components | |||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
Member of these Panels | |||
| |||
History/Usage | |||
test rank | 11896 of 2000 most commonly performed tests by labs in USA | ||
first released | |||
last updated | 2.73 | ||
last change type | MIN - change to field other than name | ||
change reason | Updated the PhenX ID from "PhenX. | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.