Gliadin peptide IgG Ab [Units/volume] in Serum by Immunoassay   63459-2

LOINC Code


LOINC code63459-2
nameGliadin peptide IgG Ab [Units/volume] in Serum by Immunoassay
statusACTIVE

Fully-Specified Name

componentGliadin peptide Ab.IgG
propertyACnc  =  Arbitrary Concentration
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemSer  =  Serum
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodIA  =  Immunoassay:  Encompasses all immunoassays with a few exceptions, including Immune Blot and Immune Fluorescence, which were created based on historic usage.

Additional Names

short nameGliadin peptide IgG Ser IA-aCnc

Basic Attributes

classSERO
type1  Laboratory
order vs. observationBoth
example UCUM units[arb'U]/mL
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitarb U/mL

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Groups

LG24121-2Gliadin peptide Ab.IgG|ACnc|Pt|ANYBldSerPl

Member of these Panels

69726-8Tissue transglutaminase IgA + Gliadin peptides IgA and IgG panel - Serum

History/Usage

test rank2582 of 2000 most commonly performed tests by labs in USA
first released
last updated2.73
last change typeMIN  - change to field other than name
change reasonThe EIA method, which was always intended to cover more than just enzyme-linked immunoassay and whose display name for the long common name has always been Immunoassay, was renamed IA in order to eliminate ambiguity about whether the method has a broader meaning than just enzyme-linked immunoassay. Likewise, EIA.rapid was renamed IA.rapid. These changes were approved by the Laboratory LOINC Committee in June 2016.

Related Names

ABS
Aby
Agf98
Antby
Anti
Antibodies
Antibody
Arbitrary concentration
Autoantibodies
Autoantibody
Celiac
Celiac disease
Deamidated gliadin peptide
Deaminated gliadin
Dermatitis Herpetiformis
DGP
DH
EIA
ELFA
ELISA
Enzyme immunoassay
F98
Gastro
Gastroenterology
GI
Gliadine
IAA
Immune globulin G
Immunoglobulin G
MEIA
Pept
Point in time
QNT
Quan
Quant
Quantitative
Random
Serology
Serum
SR
SUDS

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.