Time to rise from chair, walk 8 feet and back, and return to sitting 8UG 66217-1
LOINC Code
LOINC code | 66217-1 | ||
---|---|---|---|
name | Time to rise from chair, walk 8 feet and back, and return to sitting 8UG | ||
description | The "8-Foot Up and Go" (8UG) test measures dynamic balance and agility and is the time elapsed from a patient standing up from a chair, walking 8 feet to and around a cone (or other marker), walking back to the chair, and sitting down again in the shortest time possible.[https://doi.org/10.1123/japa.7.2.129] The 8UG, is a modified version of the "Timed Up-and-Go" (TUG) [LOINC: 89423-8], which is a modified version of the "Get-Up and Go" (GUG). TUG and 8UG are timed whereas GUG is scored on an ordinal 5 point scale. [PMID: 1991946] | ||
status | ACTIVE | ||
Fully-Specified Name | |||
component | Time to rise from chair, walk 8 feet and back, and return to sitting | ||
property | Time = Time Duration | ||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
system | ^Patient | ||
scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | ||
method | 8UG | ||
Additional Names | |||
short name | Time rise, walk 8ft, return sitting 8UG | ||
Basic Attributes | |||
class | H&P.PX | ||
type | 2 Clinical | ||
example UCUM units | s The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | ||
example unit | s | ||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
Member of these Panels | |||
| |||
History/Usage | |||
first released | |||
last updated | 2.67 | ||
last change type | MIN - change to field other than name | ||
change reason | Updated Component from "Time elapsed from the signal, go, until the participant returns to a seated position in the chair" to align with original source (8UG). Changed Method from PhenX to 8UG. Moved the Survey Question Text and Source to the Display name in Form and Observation ID fields, respectively, for this term in the PhenX Physical fitness and physical activity domain panel. Updated Status from TRIAL to ACTIVE. | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.
Thank you for choosing Find-A-Code, please Sign In to remove ads.