MR Pelvis Endorectal WO and W contrast IV 72244-7
LOINC Code
LOINC code | 72244-7 | ||||
---|---|---|---|---|---|
name | MR Pelvis Endorectal WO and W contrast IV | ||||
description | Endorectal coil magnetic resonance imaging or endorectal coil MRI is a type of medical imaging in which MRI is used in conjunction with a coil placed into the rectum in order to obtain high quality images of the area surrounding the rectum. The technique has demonstrated higher accuracy than other modalities in assessing seminal vesicle invasion and extra-capsular extension (ECE) of prostate cancer (96% and 81% respectively). Endorectal coil MRI is useful for determining the extent of spread and local invasion of cancers of the prostate, rectum, and anus. The coil consists of a probe with an inflatable balloon which helps maintain appropriate positioning. [extracted from Wikipedia http://en.wikipedia.org/wiki/Endorectal_coil_magnetic_resonance_imaging] | ||||
status | ACTIVE | ||||
Fully-Specified Name | |||||
component | Multisection endorectal^WO & W contrast IV IV = Intravenous | ||||
property | Find = Finding | ||||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||||
system | Pelvis | ||||
scale | Doc = Document: A document that could be in many formats (XML, narrative, etc.) | ||||
method | MR | ||||
Additional Names | |||||
short name | MR Pelvis Endorectal WO+W contr IV | ||||
Basic Attributes | |||||
class | RAD | ||||
type | 2 Clinical | ||||
order vs. observation | Both | ||||
Ask At Order Entry | |||||
Ask at Order Entry (AOE) observations for a clinical observation or laboratory test. A LOINC term may represent a single AOE observation or a panel containing several AOE observations.
| |||||
Associated Observations | |||||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||||
Member of these Groups | |||||
| |||||
History/Usage | |||||
first released | |||||
last updated | 2.61 | ||||
last change type | MIN - change to field other than name | ||||
change reason | The scale has been changed from "Nar" to "Doc" to fit with the CDA model.; Per Radlex/LOINC Committee we are changing the order of these components to better reflect the reality of the sequence in which they are performed (first without contrast, then with).; Method of "MRI" was changed to "MR". The LOINC/RadLex Committee agreed to use a subset of the two-letter DICOM modality codes as the primary modality identifier.; Jan 2016 Changed Component from "Multisection^W endorectal coil" to "Multisection endorectal" per LOINC/RadLex committee | ||||
Related Names | |||||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.
Thank you for choosing Find-A-Code, please Sign In to remove ads.