namePM-SCL-75 IgG Ab [Presence] in Serum or Plasma by Immunoassay
descriptionPM-SCL extractable nuclear 75kD (PM-Scl75) IgG class autoantibodies can be detected by enzyme immunoassays. Results may be interpreted by humans or automated methods and used for the diagnosis of system sclerosis (SSc, diffuse and limited forms) and overlapping syndromes. This code was created for, but not limited to, the detection of PML-Scl75 autoantibodies in Euroimmun's Systemic Sclerosis (Nucleoli) Profile EUROLINE (IgG) test kit.
statusACTIVE

Fully-Specified Name

componentPM-SCL-75 Ab.IgG
propertyPrThr  =  Present or threshold:  The Property PrThr stands for “Presence or Threshold”, meaning either a) the actual presence or absence of an analyte, or b) that the amount of analyte detected is over some predetermined threshold.
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemSer/Plas
    Ser  =  Serum
    Plas  =  Plasma
scaleOrd  =  Ordinal:  Ordered categorical responses, e.g., 1+, 2+, 3+; positive, negative; reactive, indeterminate, nonreactive.
methodIA  =  Immunoassay:  Encompasses all immunoassays with a few exceptions, including Immune Blot and Immune Fluorescence, which were created based on historic usage.

Additional Names

short namePM-SCL75 IgG SerPl Ql IA

Basic Attributes

classSERO
type1  Laboratory
order vs. observationBoth

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.56
last change typeMIN  - change to field other than name
change reasonThe PrThr property is used for LOINC terms whose results are reported using an ordered categorical scale, regardless of whether or not an internal threshold was used to make that determination. This change was approved by the Laboratory LOINC Committee in June 2016.; The EIA method, which was always intended to cover more than just enzyme-linked immunoassay and whose display name for the long common name has always been Immunoassay, was renamed IA in order to eliminate ambiguity about whether the method has a broader meaning than just enzyme-linked immunoassay. Likewise, EIA.rapid was renamed IA.rapid. These changes were approved by the Laboratory LOINC Committee in June 2016.

Related Names

ABS
Aby
Antby
Anti
Antibodies
Antibody
Autoantibodies
Autoantibody
EIA
ELFA
ELISA
Enzyme immunoassay
Evening
IAA
Immune globulin G
Immunoglobulin G
MEIA
Ordinal
Pl
Plasma
Plsm
PM-SCL75
PM-SCL-75
Point in time
Polymyositis
PR
QL
Qual
Qualitative
Random
Scleroderma
Screen
Serology
SerP
SerPl
SerPlas
Serum
Serum or plasma
SR
SUDS
Systemic Sclerosis

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.