Cytomegalovirus Ag [Presence] in Bronchoalveolar lavage by Immunofluorescence 77388-7
LOINC Code
LOINC code | 77388-7 | ||
---|---|---|---|
name | Cytomegalovirus Ag [Presence] in Bronchoalveolar lavage by Immunofluorescence | ||
description | This term was created for, but not limited in use to, the MONOFLUO KIT CMV for the detection of cytomegalovirus by indirect immunofluorescence, using using monoclonal antibodies specific for this virus. | ||
status | ACTIVE | ||
Fully-Specified Name | |||
component | Cytomegalovirus Ag | ||
property | PrThr = Present or threshold: The Property PrThr stands for “Presence or Threshold”, meaning either a) the actual presence or absence of an analyte, or b) that the amount of analyte detected is over some predetermined threshold. | ||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
system | BAL | ||
scale | Ord = Ordinal: Ordered categorical responses, e.g., 1+, 2+, 3+; positive, negative; reactive, indeterminate, nonreactive. | ||
method | IF = Immune Fluorescence: Encompasses DFA, IFA, FA. Usually applies to cells and smears examined microscopically so that both the “where” and the “what” can be assessed, but can also be used on fluids in a way similar to ELISA. Does not include Cell binding assays (see CBA IFA above). | ||
Additional Names | |||
short name | CMV Ag BAL Ql IF | ||
Basic Attributes | |||
class | MICRO | ||
type | 1 Laboratory | ||
order vs. observation | Both | ||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
Member of these Panels | |||
| |||
History/Usage | |||
first released | |||
last updated | 2.56 | ||
last change type | MIN - change to field other than name | ||
change reason | The PrThr property is used for LOINC terms whose results are reported using an ordered categorical scale, regardless of whether or not an internal threshold was used to make that determination. This change was approved by the Laboratory LOINC Committee in June 2016. | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.
Thank you for choosing Find-A-Code, please Sign In to remove ads.