Left ventricular Myocardial mass/Height exp 2.7 [Mass/Area] by US.M-mode+Calculated by cube method 77921-5
LOINC Code
LOINC code | 77921-5 | ||
---|---|---|---|
name | Left ventricular Myocardial mass/Height exp 2.7 [Mass/Area] by US.M-mode+Calculated by cube method | ||
description | The myocardial index is the left ventricular (LV) mass normalized for body size, which can be approximated by different measures including body surface area (BSA) and height. This term represents an index based on height^2.7. The cube function is a method for calculating left ventricular mass from M-mode echocardiography measurements and assumes a long- to short-axis length ratio of 2:1. The formula is as follows: LV mass = 1.04(IVSd + LVIDd + PWTd)^3 - LVID^3), where IVSd = interventricular septal thickness, LVIDd = left ventricular internal diameter (short axis), and PWTd = posterior wall thickness, all measured during end-diastole. [PMID: 2936235] | ||
status | ACTIVE | ||
Fully-Specified Name | |||
component | Myocardial mass/Height exp 2.7 | ||
property | ArMass = Mass/Area | ||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
system | Heart.ventricle.left | ||
scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | ||
method | US.M-mode+Calculated by cube method | ||
Additional Names | |||
short name | LV Myo/Ht exp 2.7 US.M-mode+cube | ||
Basic Attributes | |||
class | CARD.US | ||
type | 2 Clinical | ||
order vs. observation | Observation | ||
formula (readable) | Myocardial index = Left ventricular mass/Height exp 2.7 | ||
example UCUM units | g/{m2.7} The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | ||
example unit | g/m2.7 | ||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
History/Usage | |||
first released | |||
last updated | 2.56 | ||
last change type | MIN - change to field other than name | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.
Thank you for choosing Find-A-Code, please Sign In to remove ads.