Regurgitation degree Mitral valve Angiography   81432-7

LOINC Code


LOINC code81432-7
nameRegurgitation degree Mitral valve Angiography
descriptionAngiography is one method for determining the degree of mitral valve regurgitation. The Sellers grading system, originally published in 1964, is based on the opacification of the left atrium and is still used today. The Sellers grading system is as follows: 1) + = a regurgitant jet is visible with minimal, rapidly clearing staining of the left atrium; 2) ++ = evidence of a regurgitant jet with moderate but still rapidly clearing opacification of the left atrium; 3) +++ = the left atrium is as opaque as the left ventricle and aorta on the late films and clears slowly. A jet usually is not seen and the left atrium is usually significantly enlarged; and 4) ++++ = the left atrium is more densely opacified than the left ventricle or the aorta. The left atrium is usually markedly enlarged and the left ventricle is dilated. The left atrium remains intensely opacified on the whole series of films. [PMID: 14215054]
statusACTIVE

Fully-Specified Name

componentRegurgitation degree
propertyFind  =  Finding
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemMitral valve
scaleOrd  =  Ordinal:  Ordered categorical responses, e.g., 1+, 2+, 3+; positive, negative; reactive, indeterminate, nonreactive.
methodAngiography

Additional Names

short nameReg deg MV Angio

Basic Attributes

classCARD.PROC
type2  Clinical
order vs. observationObservation

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.56
last change typeMIN  - change to field other than name

Related Names

Angio
CARD.PROC
Cardio
Cardiology
Finding
Findings
Heart Disease
MV
Ordinal
Point in time
QL
Qual
Qualitative
Random
Reg deg
Reg degree
Screen

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.