3-Hydroxy-3-Methylglutaryl-coenzyme A reductase IgG Ab [Presence] in Serum or Plasma by Line blot   82990-3

LOINC Code


LOINC code82990-3
name3-Hydroxy-3-Methylglutaryl-coenzyme A reductase IgG Ab [Presence] in Serum or Plasma by Line blot
descriptionThis term was created for, but is not limited in use to, the submitter's test strip, a membrane strip pre-coated with a specific set of antigens in parallel lines. If antibodies to any of those antigens are present in the patient's serum, they will bind to the specific antigen. The bound patient antibodies are then detected using labelled anti-human antibodies. Various manufacturers classify this method as an immunoblot technique. LOINC uses the immunoblot (IB) method to mean that some electrophoretic/chromatographic separation occurs such that position (size) of the band is part of the assessment (as in Western blot). Because this assay does not involve a separation step but rather uses strips with pre-fixed antigens, the LOINC Method is Line blot.
statusACTIVE

Fully-Specified Name

component3-Hydroxy-3-Methylglutaryl-Coenzyme A Reductase Ab.IgG
propertyPrThr  =  Present or threshold:  The Property PrThr stands for “Presence or Threshold”, meaning either a) the actual presence or absence of an analyte, or b) that the amount of analyte detected is over some predetermined threshold.
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemSer/Plas
    Ser  =  Serum
    Plas  =  Plasma
scaleOrd  =  Ordinal:  Ordered categorical responses, e.g., 1+, 2+, 3+; positive, negative; reactive, indeterminate, nonreactive.
methodLine blot  =  Line blot:  A membrane strip pre-coated with a specific set of antigens in parallel lines that are incubated with antibodies in order to detect the targets of interest.

Additional Names

short nameHMGCR IgG SerPl Ql Line blot

Basic Attributes

classSERO
type1  Laboratory
order vs. observationBoth

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

test rank17803 of 2000 most commonly performed tests by labs in USA
first released
last updated2.73
last change typeMIN  - change to field other than name
change reasonThis term was created for an assay that uses a membrane strip pre-coated with a specific set of antigens in parallel lines. Because the antigens are seperated by electrophoresis/chromatographic separation during manufacturing, not during the test procedure itself, this test was assigned a LOINC Method of Immunoassay (IA) and not Immunoblot (IB). However, upon further review of IA, IB, and Immunoblot strip methodologies and regulatory distinctions between these, we changed the Method from IA to Line blot so that users can distinguish between these three Methods. The meaning of the term has not changed since it was created for an IB strip assay as described in the term description.

Related Names

3-OH-3-Methylglutaryl-coA reductase Ab
ABS
Aby
Antby
Anti
Antibodies
Antibody
Autoantibodies
Autoantibody
HMGCR
Hydrox
III
Immune globulin G
Immunoglobulin G
NAM
Necrotizing autoimmune myopathy
OH
Ordinal
Pl
Plasma
Plsm
Point in time
PR
QL
Qual
Qualitative
Random
Screen
Serology
SerP
SerPl
SerPlas
Serum
Serum or plasma
SR

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.