Maximum amplitude arachidonate induced [Length] in Blood by Resonance TEG 94577-4
LOINC Code
LOINC code | 94577-4 | ||
---|---|---|---|
name | Maximum amplitude arachidonate induced [Length] in Blood by Resonance TEG | ||
description | The maximum clot strength in the presence of arachidonic acid, as measured by the amplitude of resonance of the blood meniscus as the blood sample clots. In this test, thrombin activity is blocked, and arachidonic acid (AA) is used to activate platelets in order to measure the clot strength based on platelet activation by AA, which result is used to determine the relative contribution of AA-induced platelet activation [LOINC: 94579-0] to the overall clot strength [LOINC: 91125-5]. This term was created for, but is not limited in use to, the Submitter's test kit, the TEG6s PlateletMapping ADP & AA Assay Cartridge for heparinized blood. | ||
status | ACTIVE | ||
Fully-Specified Name | |||
component | Maximum clot strength amplitude.arachidonate induced | ||
property | Len = Length | ||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
system | Bld = Whole blood | ||
scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | ||
method | Thromboelastography.resonance | ||
Additional Names | |||
short name | MA AA Bld Res TEG | ||
Basic Attributes | |||
class | COAG | ||
type | 1 Laboratory | ||
order vs. observation | Observation | ||
example UCUM units | mm The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | ||
example unit | mm | ||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
History/Usage | |||
first released | |||
last updated | 2.70 | ||
last change type | NAM - change to Analyte/Component | ||
change reason | Release 2.70: COMPONENT: Updated "arachidonic acid" to "arachidonate" for consistency across LOINC Components; | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.