SARS-CoV-2 (COVID-19) N gene [Presence] in Respiratory system specimen by Nucleic acid amplification using CDC primer-probe set N1 94756-4
LOINC Code
LOINC code | 94756-4 | ||
---|---|---|---|
name | SARS-CoV-2 (COVID-19) N gene [Presence] in Respiratory system specimen by Nucleic acid amplification using CDC primer-probe set N1 | ||
description | Qualitative detection of nucleic acids within the N gene of SARS coronavirus 2 (SARS-CoV-2) in respiratory specimens by nucleic acid amplification with probe-based detection using the N1 primer-probe set developed by the Centers for Disease Control and Prevention (CDC). [CDC: coronavirus/COVID-19/lab/] | ||
status | ACTIVE | ||
Fully-Specified Name | |||
component | SARS coronavirus 2 N gene | ||
property | PrThr = Present or threshold: The Property PrThr stands for “Presence or Threshold”, meaning either a) the actual presence or absence of an analyte, or b) that the amount of analyte detected is over some predetermined threshold. | ||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||
system | Respiratory System Specimen | ||
scale | Ord = Ordinal: Ordered categorical responses, e.g., 1+, 2+, 3+; positive, negative; reactive, indeterminate, nonreactive. | ||
method | Probe.amp.tar.CDC primer-probe set N1 | ||
Additional Names | |||
short name | SARS-CoV-2 N gene Resp Ql NAA N1 | ||
Basic Attributes | |||
class | MICRO | ||
type | 1 Laboratory | ||
order vs. observation | Observation | ||
panel type | 81959-9 | ||
Associated Observations | |||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||
History/Usage | |||
first released | |||
last updated | 2.75 | ||
last change type | MAJ - change to name field other than Component; | ||
change reason | Release 2.75: SYSTEM: There are 2 similar system's in LOINC: 1- Respiratory system 2- Respiratory specimen Due to an applied logic, the display in the System axis for 1 is Respiratory (adjective) without specification of sample, specimen, or other specific noun, while 2 is displayed fully as Respiratory specimen. Therefore for now we replaced 1 with Respiratory system specimen, which will affect 83 term. The result is replacing "Respiratory" with "Respiratory system specimen". This is the short approach. The bigger project is to potentially merge data that has either 1 or 2 together. This is a project to pass by the laboratory committee and will involve about 1500 concepts.; | ||
Related Names | |||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.