Rate of fibrin formation.diatomaceous earth induced [Units] in Blood by Microviscometry   96694-5

LOINC Code


LOINC code96694-5
nameRate of fibrin formation.diatomaceous earth induced [Units] in Blood by Microviscometry
descriptionMicroviscometer analyzers used clinically for coagulation assays commonly report a unit for clot formation that monotonically increases with increasing viscosity but is not a standard viscosity unit such as centipoise. The clot unit produced by these assays has a long historical precedent. It is considered a measure of viscosity of a liquid prior to clot formation and the viscous component of a viscoelastic gel after clot formation, albeit reported on a continuous scale.
statusACTIVE

Fully-Specified Name

componentRate of fibrin formation.diatomaceous earth induced
propertyARat  =  Arbitrary Rate
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBld  =  Whole blood
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodMicroviscometry

Additional Names

short nameClot Rate Diatom Earth Ind Bld MicrVisc

Basic Attributes

classCOAG
type1  Laboratory
order vs. observationObservation
example UCUM units{Clot_signal_units}/min
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unitClot signal units/min

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.75
last change typeMIN  - change to field other than name

Related Names

Arbitrary rate
Blood
Celite
Clot Rate Diatom Earth Ind
COAGULATION
Hematology
Heme
MicrVisc
Point in time
QNT
Quan
Quant
Quantitative
Random
WB
Whole blood

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.