Reduction in kaolin+tissue factor induced clot strength [Length fraction] in Blood --30 minutes post maximum clot amplitude   97012-9

LOINC Code


LOINC code97012-9
nameReduction in kaolin+tissue factor induced clot strength [Length fraction] in Blood --30 minutes post maximum clot amplitude
descriptionThrombelastography determination of percentage of clot strength lost due to fibrinolysis 30 minutes after maximum clot strength obtained, stimulated with kaolin and tissue factor.
statusACTIVE

Fully-Specified Name

componentReduction in clot strength.kaolin+tissue factor induced^30M post maximum clot amplitude
    30M  =  30 minutes post challenge
propertyLenFr  =  Length Fraction
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemBld  =  Whole blood
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
method

Additional Names

short nameLysis kao+TF ind clot 30M p MA LenFr Bld

Basic Attributes

classCOAG
type1  Laboratory
order vs. observationObservation
example UCUM units%
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unit%

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

History/Usage

first released
last updated2.70
last change typeADD  - added

Related Names

30M p MA
After
Blood
COAGULATION
Fac
Fact
Hematology
Heme
Length Fraction
Lysis of kao+TF ind clot
Percent
Point in time
PST
QNT
Quan
Quant
Quantitative
Random
WB
Whole blood

Copyright © 2023 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2023, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.

demo
request yours today
subscribe
start today
newsletter
free subscription

Thank you for choosing Find-A-Code, please Sign In to remove ads.