NM Salivary gland Views for function 81572-0
LOINC Code
LOINC code | 81572-0 | ||||
---|---|---|---|---|---|
name | NM Salivary gland Views for function | ||||
description | Nuclear salivary gland imaging can be done to evaluate salivary gland function as well as patency of the salivary duct and salivary tumors. In the first phase, dynamic blood flow is oberved immediately after pertechnetate injection, and then dynamic imaging is done for about 20 minutes to evaluate gland uptake. Appearance of pertechnetate should begin a minute after injection and reach its peak between 10 and 20 minutes. In the second phase of the study, the patient is given lemon juice to drink, which stimulates the excretory function of the glands. In the second phase, either static images or longer dynamic acquisition that covers both the pre- and post- stimulus phases may be used may be acquired. With normal salivary gland functioning, the amount of pertechnetate visualized in the glands should begin to decrease almost immediately after lemon stimulation. [PMID: 19223429] | ||||
status | ACTIVE | ||||
Fully-Specified Name | |||||
component | Views for function^W radionuclide IV IV = Intravenous | ||||
property | Find = Finding | ||||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||||
system | Head>Salivary gland | ||||
scale | Doc = Document: A document that could be in many formats (XML, narrative, etc.) | ||||
method | NM | ||||
Additional Names | |||||
short name | NM Salivary gland Vs function W RNC IV | ||||
Basic Attributes | |||||
class | RAD | ||||
type | 2 Clinical | ||||
order vs. observation | Both | ||||
Ask At Order Entry | |||||
Ask at Order Entry (AOE) observations for a clinical observation or laboratory test. A LOINC term may represent a single AOE observation or a panel containing several AOE observations.
| |||||
Associated Observations | |||||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||||
Member of these Groups | |||||
| |||||
History/Usage | |||||
first released | |||||
last updated | 2.64 | ||||
last change type | MIN - change to field other than name | ||||
Related Names | |||||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.
Thank you for choosing Find-A-Code, please Sign In to remove ads.