dRVVT W excess phospholipid actual/normal (normalized LA confirm) 68916-6
LOINC Code
LOINC code | 68916-6 | ||||
---|---|---|---|---|---|
name | dRVVT W excess phospholipid actual/normal (normalized LA confirm) | ||||
description | If the coagulation defect corrects with excess phospholipid, it confirms the likely presence of phospholipid antibodies and the LA syndrome. Platelets, bilayer and hexagonal phospholipids are variously used as the source of excess phospholipids and this term covers them all. The use of one term for these variations reduces mapping work for practices that import laboratory results, but laboratories that use hexagonal phospholipids and think it important to distinguish their source can use 75913-4 instead of this term. | ||||
status | ACTIVE | ||||
Fully-Specified Name | |||||
component | Coagulation dilute Russell viper venom induced.excess phospholipid actual/Normal | ||||
property | RelTime = Relative Time | ||||
time | Pt = Point in time: To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements. | ||||
system | PPP = Platelet poor plasma | ||||
scale | Qn = Quantitative: The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256 | ||||
method | Coag = Coagulation Assay: To distinguish coagulation assays based on clotting methods that test function/activity from Immune methods that detect the presence of clotting factors and may or may not be functional assays. | ||||
Additional Names | |||||
short name | Confirm dRVVT/normal | ||||
Basic Attributes | |||||
class | COAG | ||||
type | 1 Laboratory | ||||
order vs. observation | Observation | ||||
example UCUM units | % The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org) | ||||
example unit | % | ||||
Associated Observations | |||||
LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations. | |||||
Member of these Panels | |||||
| |||||
History/Usage | |||||
test rank | 16748 of 2000 most commonly performed tests by labs in USA | ||||
first released | |||||
last updated | 2.73 | ||||
last change type | MIN - change to field other than name | ||||
Related Names | |||||
|
Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.
Thank you for choosing Find-A-Code, please Sign In to remove ads.