aPTT.lupus sensitive W excess phospholipid percent correction   75507-4

LOINC Code


LOINC code75507-4
nameaPTT.lupus sensitive W excess phospholipid percent correction
descriptionThe aPTT percent correction formula is based on the 2009 International Society on Thrombosis and Haemostasis lupus anticoagulant testing guidelines. [PMID:19624461]
statusACTIVE

Fully-Specified Name

componentCoagulation surface induced.lupus sensitive percent correction
propertyPctDiff  =  Percent Difference
timePt  =  Point in time:  To identify measures at a point in time. This is a synonym for “spot” or “random” as applied to urine measurements.
systemPPP  =  Platelet poor plasma
scaleQn  =  Quantitative:  The result of the test is a numeric value that relates to a continuous numeric scale. Reported either as an integer, a ratio, a real number, or a range. The test result value may optionally contain a relational operator from the set {<=, <, >, >=}. Valid values for a quantitative test are of the form "7", "-7", "7.4", "-7.4", "7.8912", "0.125", "<10", "<10.15", ">12000", 1-10, 1:256
methodCoag  =  Coagulation Assay:  To distinguish coagulation assays based on clotting methods that test function/activity from Immune methods that detect the presence of clotting factors and may or may not be functional assays.

Additional Names

short nameaPTT % correction

Basic Attributes

classCOAG
type1  Laboratory
order vs. observationBoth
formula (readable)[(Screen aPTT - Confirm aPTT)/Screen aPTT] x 100
example UCUM units%
The Unified Code for Units of Measure (UCUM) is a code system intended to include all units of measures being contemporarily used in international science, engineering, and business (www.unitsofmeasure.org)
example unit%

Associated Observations

LOINC codes that represent optional associated observation(s) for a clinical observation or laboratory test. A LOINC term may represent a single associated observation or panel containing several associated observations.

Member of these Panels

75515-7Lupus anticoagulant aPTT and dRVVT screening panel W Reflex
75881-3Lupus anticoagulant aPTT, dRVVT and PT screening panel W Reflex

History/Usage

first released
last updated2.73
last change typeMIN  - change to field other than name

Related Names

Activated partial thromboplastin time
aPTT
aPTT with Platelin LS
aPTT-LA
aPTT-LA % correction
Clot
Clottable
Coag
Coagulation assay
Correctn
Hematology
Heme
Little(A)PTT
Partial Thromboplastin Time
Plas
Platelet poor plasma
Point in time
PTT
QNT
Quan
Quant
Quantitative
Random
Surf
Tilt tube

Copyright © 2024 Regenstrief Institute, Inc. All Rights Reserved. To the extent included herein, the LOINC table and LOINC codes are copyright © 1995-2024, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee. See https://loinc.org/license for the full LOINC copyright and license.